During ablation, digital data is not drawn on RF window

* A nine pin serial extension cable must be connected from COM2 (Serial 2 or Serial B) on the main computer to the serial port on the back of the ablation generator. The DEVICE field on the RF window must be selected to the correct value.

Reinhard Schmidt Termination

Only flat line real-time signals, or message stating "AMPLIFIER FAILURE", or message stating "NO VALID SIGNALS ARE PRESENT"

* The amplifier must be turned on.
* Check for communication between the amplifier and main computer using the Communication Test from the Help button menu in Windows or from the main menu in DOS to see if the amplifier is functioning.
* The wrong amplifier communication driver is installed. Was the system just upgraded or a backup restored? See the User's Manual, chapter 11, for more details on configuring the main computer to match the amplifier.
* The ethernet cable (BNC) must be attached between the ethernet card of the amplifier and the main computer. Check that the BNC cable running from the amplifier to the computer must be terminated by 50 Ohm terminators at each end. Most cards are terminated internally and would have a sticker stating this. If there is no termination sticker, each 10-BASE T board must have a BNC 'T' adapter and a 50 Ohm terminator attached.
* Turn the amplifier off and then on. The amplifier beeps as it boots up in progressively higher tones spaced seconds apart. If it is beeping and the boards are seated then this amplifier is probably OK. See Users Manual, chapter 11 for more details about the exact sequence of beeps.
* The Amplifier card(s) may be dislodged. Please take the cover off and make sure all boards are seated correctly.
* Turn the system off and then on.

Reinhard Schmidt Termination System will not copy to disk

* Check to make sure the disk is formatted by EPMedSystems. EPMedSystems does not approve of the end-user formatting optical disks on the EP-Workmate as there is a likely potential for data loss or for formatting the hard drive and disabling the system.

Ep Medsystems Termination


Small gray dots or lines appear on review or real-time monitor

* In the realtime monitor window controls, select the GRID(#) button and set each value to 0. In the cathmap setup screen, set the clip value of each channel to Off.

Reinhard Schmidt Termination West Berlin, NJ (March 13, 2008)--EP MedSystems, Inc. (NASDAQ: EPMD)

The Company’s net loss was $2.1 million, or $.07 per share, for the fourth quarter of 2007, and $5.5 million, or $.18 per share, for fiscal 2007. After excluding business realignment charges, adjusted net loss in the fourth quarter was $787,000, or $0.03 per share, and $4.2 million, or $0.14 per share, for the full year ended December 31, 2007. See the attached reconciliation of the Company’s non-GAAP adjusted diluted earnings per share to the Company’s GAAP diluted earnings per share.

David Bruce commented, “In 2007 we made significant progress growing revenue to record levels, penetrating the ultrasound catheter market, substantially increasing customer satisfaction with our products and services, and developing new products for 2008. Beginning this month we have started shipping our WorkMate® 4.0 products with ClearWave™ technology delivering a significant improvement in clarity of signals, a top factor considered when customers select an EP Recording System.

Don't miss out, learn more: Ep Medsystems Termination , Reinhard Schmidt Epmd , Reinhard Schmidt Epmd





Tags:




Reinhard Schmidt's Profile


Latest Posts


Reinhard Schmidt

Monthly Archive


November 2009

Change Language




Tags Archive


epmedsystemstermination reinhardschmidtepmd

Filter By Type


Travel

Friends
Reinhard Schmidt


125 views
Important Disclaimer